Relative motion Control
Control law: \(f = -G(x-w)\)
\[ \frac{x}{w} = \frac{k+G}{ms^2 + k+G} \] \[ \frac{x}{F} = \frac{1}{ms^2 + k+G} \]
Force Control
Control law: \(f = -G F_a = -G \left(f-k(x-w)\right)\)
\[ \frac{x}{w} = \frac{k}{(1+G)ms^2 + k} \] \[ \frac{x}{F} = \frac{1+G}{(1+G)ms^2 + k} \]
Inertial Control
Control law: \(f = -Gx\)
\[ \frac{x}{w} = \frac{k}{ms^2 + k+G} \] \[ \frac{x}{F} = \frac{1}{ms^2 + k+G} \]
Design constraints and control bandwidth
Heavier sensor => lower noise but it is harder to maintain collocation with the actuator => that limits the bandwidth. There is a compromise between sensor noise and the influence of the sensor size on the system’s design and on the control bandwidth.
Bibliography
Tjepkema, D., J. van Dijk, and H. M. J. R. Soemers. 2012. “Sensor Fusion for Active Vibration Isolation in Precision Equipment.” Journal of Sound and Vibration 331 (4): 735–49. doi:10.1016/j.jsv.2011.09.022.