Tags
Sensor Fusion, Vibration Isolation
Reference
(Tjepkema, van Dijk, and Soemers 2012)
Author(s)
Tjepkema, D., Dijk, J. v., & Soemers, H.
Year
2012

Relative motion Control

Control law: \(f = -G(x-w)\)

\[ \frac{x}{w} = \frac{k+G}{ms^2 + k+G} \] \[ \frac{x}{F} = \frac{1}{ms^2 + k+G} \]

Force Control

Control law: \(f = -G F_a = -G \left(f-k(x-w)\right)\)

\[ \frac{x}{w} = \frac{k}{(1+G)ms^2 + k} \] \[ \frac{x}{F} = \frac{1+G}{(1+G)ms^2 + k} \]

Inertial Control

Control law: \(f = -Gx\)

\[ \frac{x}{w} = \frac{k}{ms^2 + k+G} \] \[ \frac{x}{F} = \frac{1}{ms^2 + k+G} \]

Design constraints and control bandwidth

Heavier sensor => lower noise but it is harder to maintain collocation with the actuator => that limits the bandwidth. There is a compromise between sensor noise and the influence of the sensor size on the system’s design and on the control bandwidth.

Bibliography

Tjepkema, D., J. van Dijk, and H. M. J. R. Soemers. 2012. “Sensor Fusion for Active Vibration Isolation in Precision Equipment.” Journal of Sound and Vibration 331 (4): 735–49. doi:10.1016/j.jsv.2011.09.022.