Electronic Active Filters
Contents
Second Order Low Pass Filter
\begin{equation} \frac{V_o}{V_i}(s) = \frac{1}{R^2 C_1 C_2 s^2 + 2 R C_2 s + 1} \end{equation}
\begin{equation} \frac{V_o}{V_i}(s) = \frac{1}{\frac{s^2}{\omega_0^2} + 2 \zeta \frac{s}{\omega_0} + 1} \end{equation}
With:
- \(\omega_0 = \frac{1}{R\sqrt{C_1 C_2}}\)
- \(\zeta = \frac{C_2}{C_1}\)
The input impedance is \(V_i/i_i\).

Figure 1: Second Order Low Pass Filter
Second Order High Pass Filter
Same as Figure 1 but by exchanging R1 with C1 and R2 with C2
\begin{equation} \frac{V_o}{V_i}(s) = \frac{R^2 C_1 C_2 s^2}{R^2 C_1 C_2 s^2 + 2 R C_2 s + 1} \end{equation}
With:
- \(\omega_0 = \frac{1}{R\sqrt{C_1 C_2}}\)
- \(\zeta = \frac{C_2}{C_1}\)
PID controller
See The design of high performance mechatronics - third revised edition (Chapter 6.2.6).